what is the units of angle random walk in (Inertial Sensor Noise Analysis)

11 views (last 30 days)
hello
i wants to know the units of angle random walk, Rate Random Walk, Bias Instability mentioned in
thanks

Answers (1)

Diarmaid Cualain
Diarmaid Cualain on 4 Mar 2021
Edited: Diarmaid Cualain on 4 Mar 2021
Yea, it isnt clear in the documentation.
  • ARW is (rad/s)/√Hz.
  • RRW is (rad/s)(√Hz).
  • Bias instability is rad/s.
You can tell, because at the end of the guide they use the function https://uk.mathworks.com/help/fusion/ref/gyroparams.html where the units are listed.
  • ARW is also called N, white noise, noise density or power spectral density of sensor noise.
  • RRW is also called K, red noise, Brownian noise. It is the integrated white noise.
  • Bias instability is also called B, pink noise, flicker, or instability of the bias offset
  1 Comment
Mazen Maged
Mazen Maged on 16 Apr 2021
Hi Diarmaid,
Could you explain what are the units of Allan Variance and Allan Deviation used in the example? I think they should depend on the units of omega (rad/s)?

Sign in to comment.