Clear Filters
Clear Filters

Simulink integrator block initial conditions

3 views (last 30 days)
Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;

Accepted Answer

Fangjun Jiang
Fangjun Jiang on 5 Feb 2019
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
  4 Comments
Fangjun Jiang
Fangjun Jiang on 23 Apr 2021
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
Wang Tao on 24 Apr 2021
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.

Sign in to comment.