How to simulate a rotor inter-turn fault in synchronous generator,using matlab programme.
10 views (last 30 days)
Show older comments
I need programme format for simulating rotor inter-turn fault in synchronous generator.
0 Comments
Answers (1)
Sabin
on 26 Jun 2025
Normally we can model electrical machines by representing each winding as a single entity with associated inductance, electromotive force, and mutual inductive coupling to adjacent windings. However, when a winding fault occurs, the single entity assumption breaks down. To correctly capture the resulting dynamics, you have to model the motor at a winding level. This requires modeling in the magnetic domain. Simscape Electrical has an example of a faulted PMSM that may be used as a starting point:
2 Comments
chen wenbo
on 10 Jul 2025
Thank you to the developers for their works. Currently, this model only supports surface-mounted motors. What should I do if I want to simulate motors with embedded permanent magnet?
See Also
Categories
Find more on Machines in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!