How can I use the National Instruments PCI- and PXI-623x series devices with the Data Acquisition Toolbox 2.8.1 (R2006a)?

2 views (last 30 days)
I would like to use the following NI PCI- and PXI-623x series devices with the Data Acquisition Toolbox 2.8.1(R2006a):
PCI-6230
PXI-6230
PCI-6232
PXI-6232
PCI-6233
PXI-6233

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 27 Jun 2009
This enhancement has been incorporated in Release 2007a (R2007a). For previous product releases, read below for any possible workarounds:
The National Instruments PCI-623x series devices are not supported by the Data Acquisition Toolbox 2.8.1 (R2006a).
To work around this issue, perform these steps to add support for these devices:
1. Quit MATLAB.
2. Find the following file:
$MATLAB\toolbox\daq\daq\private\mwnidaqmx.ini
where $MATLAB is the MATLAB root installation directory obtained by issuing:
matlabroot
at the MATLAB Command Prompt.
3. Make a copy of this file and rename it to mwnidaqmx.ini.old.
4. Open the file mwnidaqmx.ini in a text editor, and add the following lines at the end of the file:
[PCI-6230]
;bank isolated, 8 AI channel, 250 kS/s, 16-bit M Series device
hasAnalogInput = true
numAIChannels = 8
hasAnalogOutput = true
numAOChannels = 4
maxAOSampleRate = 500000,450000,425000,400000
hasDigitalIO = true
digitalPortSize = 6,4
digitalPortCap = 1,2
[PXI-6230]
;bank isolated, 8 AI channel, 250 kS/s, 16-bit M Series device
hasAnalogInput = true
numAIChannels = 8
hasAnalogOutput = true
numAOChannels = 4
maxAOSampleRate = 500000,450000,425000,400000
hasDigitalIO = true
digitalPortSize = 6,4
digitalPortCap = 1,2
[PCI-6232]
;250 KS/s, 16-bit, 16 single-ended or 8 differential AI channel isolated M Series device (sourcing DO)
hasAnalogInput = true
numAIChannels = 16
hasAnalogOutput = true
numAOChannels = 2
maxAOSampleRate = 500000,450000
hasDigitalIO = true
digitalPortSize = 6,4
digitalPortCap = 1,2
[PXI-6232]
;250 KS/s, 16-bit, 16 single-ended or 8 differential AI channel isolated M Series device (sourcing DO)
hasAnalogInput = true
numAIChannels = 16
hasAnalogOutput = true
numAOChannels = 2
maxAOSampleRate = 500000,450000
hasDigitalIO = true
digitalPortSize = 6,4
digitalPortCap = 1,2
[PCI-6233]
;250 KS/s, 16-bit, 16 single-ended or 8 differential AI channel isolated M Series device (sinking DO)
hasAnalogInput = true
numAIChannels = 16
hasAnalogOutput = true
numAOChannels = 2
maxAOSampleRate = 500000,450000
hasDigitalIO = true
digitalPortSize = 6,4
digitalPortCap = 1,2
[PXI-6233]
;250 KS/s, 16-bit, 16 single-ended or 8 differential AI channel isolated M Series device (sinking DO)
hasAnalogInput = true
numAIChannels = 16
hasAnalogOutput = true
numAOChannels = 2
maxAOSampleRate = 500000,450000
hasDigitalIO = true
digitalPortSize = 6,4
digitalPortCap = 1,2
5. Save the file mwnidaqmx.ini and restart MATLAB.