Is it possible to modify the Op-Amps to allow interaction with an external signal in SimElectronics 1.3 (R2009b)?

1 view (last 30 days)
I am trying to model a Flyback Converter, which has a PWM controller. This PWM controller has 3 Op-Amp(s), and their supply voltages arrive from somewhere in the electrical circuit.
These supply voltages are not of a fixed value but a parameter.
I would like to be able to control the supply voltages by means of connecting them to somewhere in the circuit itself.

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 25 Nov 2009
The ability to modify the Op-Amp to allow interaction with an external signal is not available in SimElectronics 1.3(R2009b).
As a workaround, you can modify the .ssc file for the Standard Op-Amp in the Simscape foundation library to meet the same requirements.