Why do I receive a signal mismatch error when I use the Sequence Analyzer (Phasor Type) in SimPowerSystems?

10 views (last 30 days)
I am using the Sequence Analyzer (Phasor Type). When I attempt to simulate the model I get the following error:
Output port complex signal mismatch. If all inputs of the Sum block are real signals,
then the output of the block must be a real signal. All inputs of block
'test_phasors/Sequence Analyzer (Phasor Type)/Zero Seq. Computation/Sum' are real signals.
However, the output port of the block is a complex signal

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 27 Jun 2009
This bug has been fixed for Release 14 (R14). For previous releases, please read below for any possible workarounds:
The Sequence Analyzer block (Phasor Type) is only valid in a Phasor simulation of a model. This can be set by using the powergui block found in the main SimPowerSystem folder in the Simulink Library Browser. If you want to keep the model as a Continuous model, you need to use the 3-Phase Sequence Analyzer block found in the Measurements library under the Extra Library of SimPowerSystems Blockset.
  1 Comment
Sandip Kumar
Sandip Kumar on 5 Dec 2013
Edited: MathWorks Support Team on 11 Jun 2018
Hi efrain,
Sorry for the delay in responding. It seems this is a technical question, and for all technical enquiries, please create a service request at the following link with all the information: https://www.mathworks.com/support/servicerequests/create.html

Sign in to comment.