Why am I unable to run the demos for Link for ModelSim 1.1 (R13SP1) with the Simulink/ModelSim co-simulation running in shared-memory mode?

2 views (last 30 days)
I have experienced this problem intermittently having run the VISM command with the manchester receiver models, pressing the play button usually gives me the following error message:
Error reported by S-function 'smtifli' in block
'manchestermodelcommblks/VHDL Manchester Receiver':
Failed to connect to server. Make sure the loaded ModelSim model is using
shared memory
I am using a laptop with Windows XP. I did not experience this issue on my previous laptop running Windows 2000. I have Modelsim SE 5.8a installed on both.

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 27 Jun 2009
This bug has been fixed for Release 14 SP1 (R14SP1). For previous releases, please read below for any possible workarounds:
This has been verified as a bug in Link for ModelSim 1.1 (R13SP1) in the way that it handles co-simulation running in shared-memory mode.
Currently, to work around this issue, try un-checking the shared memory option and sending it through TCP/IP even though ModelSim is on the same machine.